Item | Inspection Method | Unit | GF20 | GF30 | FRPBTGF20 | FRPBTGF30 | FRPBTGF30-1 | ||||||
Tensile strength | ISO527-2 | MPa | 120 | 150 | 100 | 145 | 90 | ||||||
Elongation | ISO527-2 | % | - | - | - | - | - | ||||||
Bending strength | ISO178 | MPa | 180 | 220 | 170 | 215 | 180 | ||||||
Bending modulus | ISO178 | MPa | 6500 | 10000 | 5500 | 11500 | 9000 | ||||||
Notch impact strength of simply supportted beam | ISO179-1 | KJ/m2 | 6 | 14 | 4 | 9 | 8 | ||||||
Notch impact of strength of cantilever beam | ISO180 | KJ/m2 | 7 | 15 | 6 | 10 | 8 | ||||||
Denstity | ISO1183 | g/cm3 | 1.45 | 1.55 | 1.53 | 1.62 | 1.52 | ||||||
Ash | ISO3451 | % | 20±1.5 | 30±1.5 | 20±2 | 30±2 | 30±2 | ||||||
CTI | IEC60112 | V | 250 | 250 | 250 | 250 | 400 | ||||||
Flame retardant | UL-94 | / | HB | HB | 1.5mmV0 | 1.5mmV0 | 1.5mmV0 | ||||||
Product application | Electric tool parts, fan blades, motor frame, electric appliance, meter wiring slot |